Ecoendoscopia: pasado, presente y futuro de un viaje al espacio interior
DOI:
https://doi.org/10.47892/rgp.2024.441.1675Palabras clave:
EcoendoscopiaDescargas
Métricas
Citas
DiMagno EP, Buxton JL, Regan PT, Hattery RR, Wilson DA, Suarez JR, Green PS. Ultrasonic endoscope. Lancet. 1980;1(8169):629-31. doi: 10.1016/s0140-6736(80)91122-8.
Dimagno EP, Regan PT, Clain JE, James EM, Buxton JL. Hu- man endoscopic ultrasonography. Gastroenterology. 1982;83(4):824-9.
ASGE Standards of Practice Committee; Buxbaum JL, Abbas Fehmi SM, Sultan S, Fishman DS, Qumseya BJ, et al. ASGE guideline on the role of endoscopy in the evaluation and management of choledocholithiasis. Gastrointest Endosc. 2019;89(6):1075-1105.e15. doi: 10.1016/j.gie.2018.10.001.
Dumonceau JM, Deprez PH, Jenssen C, Iglesias-Garcia J, Larghi A, Vanbiervliet G, et al. Indications, results, and clinical impact of endoscopic ultrasound (EUS)-guided sampling in gastroen- terology: European Society of Gastrointestinal Endoscopy (ESGE) Clinical Guideline - Updated January 2017. Endoscopy. 2017;49(7):695-714. doi: 10.1055/s-0043-109021.
Arango Molano LA, Sánchez Gil A, Diaz Tovar CP, Valencia Uri- be A, Ospina Pérez CG, Cuervo Pico PE, et al. Rendimiento diagnóstico de la endosonografía biliopancreática en pacien- tes con riesgo intermedio de coledocolitiasis. Rev Gastroen- terol Peru. 2024;44(1):8-13. doi: 10.47892/rgp.2023.441.1648.
Li Salvatierra B, Calixto-Aguilar L, Ramos-Castillo W, Cha- caltana Mendoza A. Efectividad y seguridad de la biopsia hepática guiada por endosonografía en enfermedad he- pática en un hospital público de nivel III. Rev Gastroen- terol Perú. 2023;43(4):341-7. doi: 10.47892/ rgp.2023.434.1592.
Stavropoulos SN, Im GY, Jlayer Z, Harris MD, Pitea TC, Turi GK, et al. High yield of same-session EUS-guided liver biopsy by 19-gauge FNA needle in patients undergoing EUS to exclude biliary obstruction. Gastrointest Endosc. 2012;75(2):310-8. doi: 10.1016/j.gie.2011.09.043.
Mok SRS, Diehl DL, Johal AS, Khara HS, Confer BD, Mudireddy PR, et al. prospective pilot comparison of wet and dry he- parinized suction for EUS-guided liver biopsy (with videos). Gastrointest Endosc. 2018;88(6):919-925. doi: 10.1016/j. gie.2018.07.036.
Ching-Companioni RA, Diehl DL, Johal AS, Confer BD, Kha- ra HS. 19G aspiration needle versus 19G core biopsy needle for endoscopic ultrasound-guided liver biopsy: a prospecti- ve randomized trial. Endoscopy. 2019;51(11):1059-1065. doi: 10.1055/a-0956-6922.
Swahn FP, Lukas G, Glavas R, Wickbom M. Endodrill Model X biopsy instrument, the advent of the first EUS guided 17 Gau- ge core needle biopsy (CNB). Gastroenterology. 2022;162(7 Suppl 1):S472.
Binmoeller KF, Shah J. A novel lumen-apposing stent for translu- minal drainage of nonadherent extraintestinal fluid collections. Endoscopy. 2011;43(4):337-42. doi: 10.1055/s-0030-1256127.
Melki G, Mohamed A, Cavanagh Y, Baddoura W, Grossman M. Perivesicular Abscess Drainage with Lumen-Apposing Self- Expanding Metal Stents. Middle East J Dig Dis. 2020;12(3):206- 210. doi: 10.34172/mejdd.2020.183.
Othman M, Patel K, Krishna SG, Mendoza-Ladd A, Verco S, Abidi W, et al. E Early phase trial of intracystic injection of lar- ge surface area microparticle paclitaxel for treatment of mu- cinous pancreatic cysts. Endosc Int Open. 2022;10(12):E1517- E1525. doi: 10.1055/a-1949-7730.
Sharma NR, Lo SK, Hendifar A, Othman MO, Patel K, Men- doza-Ladd A, et al. Response of Locally Advanced Pancrea- tic Cancer to Intratumoral Injection of Large Surface Area Microparticle Paclitaxel: Initial Report of Safety and Clinical
Outcome. Pancreas. 2023;52(3):e179-e187. doi: 10.1097/MPA.0000000000002236.
Machicado JD, Chao WL, Carlyn DE, Pan TY, Poland S, Alexander VL, et al. High performance in risk stratification of in- traductal papillary mucinous neoplasms by confocal laser endomicroscopy image analysis with convolutional neural networks (with video). Gastrointest Endosc. 2021;94(1):78-87. e2. doi: 10.1016/j.gie.2020.12.054.
Machicado JD, Napoleon B, Lennon AM, El-Dika S, Pereira SP, Tan D, et al. Accuracy and agreement of a large panel of endosonographers for endomicroscopy-guided virtual biopsy of pancreatic cystic lesions. Pancreatology. 2022;22(7):994-1002. doi: 10.1016/j.pan.2022.08.012.
Huang JY, Samarasena JB, Tsujino T, Lee J, Hu KQ, McLaren CE, et al. EUS-guided portal pressure gradient measurement with a simple novel device: a human pilot study. Gastrointest Endosc. 2017;85(5):996-1001. doi: 10.1016/j.gie.2016.09.026.
Edelson JC, Mitchell NE, Rockey DC. Endohepatology - cu- rrent status. Curr Opin Gastroenterol. 2022;38(3):216-220. doi: 10.1097/MOG.0000000000000839.
Descargas
Publicado
Cómo citar
Número
Sección
Licencia
Derechos de autor 2024 Antonio Mendoza Ladd
Esta obra está bajo una licencia internacional Creative Commons Atribución 4.0.
Revista de Gastroenterología del Perú by Sociedad Peruana de Gastroenterología del Perú is licensed under a Licencia Creative Commons Atribución 4.0 Internacional..
Aquellos autores/as que tengan publicaciones con esta revista, aceptan los términos siguientes:
- Los autores/as conservarán sus derechos de autor y garantizarán a la revista el derecho de primera publicación de su obra, el cuál estará simultáneamente sujeto a la Licencia de reconocimiento de Creative Commons que permite a terceros compartir la obra siempre que se indique su autor y su primera publicación esta revista.
- Los autores/as podrán adoptar otros acuerdos de licencia no exclusiva de distribución de la versión de la obra publicada (p. ej.: depositarla en un archivo telemático institucional o publicarla en un volumen monográfico) siempre que se indique la publicación inicial en esta revista.
- Se permite y recomienda a los autores/as difundir su obra a través de Internet (p. ej.: en archivos telemáticos institucionales o en su página web) antes y durante el proceso de envío, lo cual puede producir intercambios interesantes y aumentar las citas de la obra publicada. (Véase El efecto del acceso abierto).